Este sitio Web utiliza cookies propias y de terceros con objeto de mejorar la experiencia de navegación. Si continúa navegando estará aceptando de forma expresa el uso de estas cookies. Puede obtener más información en nuestra página Uso de Cookies

Accept
  • SMOKE OPTICAL DENSITY CHAMBER (CA01 / CA03) - noselab
  • SMOKE OPTICAL DENSITY CHAMBER (CA01 / CA03) - noselab
  • SMOKE OPTICAL DENSITY CHAMBER (CA01 / CA03) - noselab

SMOKE OPTICAL DENSITY CHAMBER (CA01 / CA03) - noselab

Cod: 430801 / 430802Standard: ASTM E 662, NFPA 258, ISO 5659-2, EN 45545-2.

CA01 Smoke Density Chamber in compliance with ASTM E 662 for determine the specific optical density of smoke generated by materials solids mounted in vertical position, with thicknesses up to 25 mm.

Model CA03 in accordance with the ISO 5659 standard adopts a furnace radiant heat (900W) to test in a horizontal position.

Contact Form

You can get in touch with us filling the contact form below.

REQUEST ESTIMATE
    • Share:

    • CA01 Smoke Density Chamber in compliance with ASTM E 662 for determine the specific optical density of smoke generated by materials solids mounted in vertical position, with thicknesses up to 25 mm.

      The use of a radiant energy source and a six burner flames reproduces irradiation conditions at the same time and combustion. While the smoke produced by the specimen accumulates in the sealed chamber a photometric system determines the optical transmittance variations.

    • Model CA03 in accordance with the ISO 5659 standard adopts a furnace radiant heat (900W) to test in a horizontal position.

      Photometric system with vertical light beam with parallel optics, silicon photodiode detector with spectral response similar to the S-4. Transmittance measurement range from 100 to 0.00001 in four scales, automatic zeroing.

      Test data and specific optical density management are displayed on Personal Computers. DataLink Software handles them all the functions of opening and closing valves, calibration of the light beam, as well as to proceed with the test automatically. Reports of test with transmittance value diagrams, test archive.

    • A gas sampling system can be adopted, FT-IR with gas chromatographic analysis using EGA modules for extraction, filtration and thermal stabilization of exhaust gases (up to 10 l / min). System developed according to EN 45545-2 , ISO 5659-2.