Parameters to survey:
- Post-combustion time.
- Post-incandescence time.
- Measurement of the damaged zone.
- Emission of fired drops.
- Emission of fired or red-hot particles.
Technical specifications:
- Stainless-steel AISI 304 combustion chamber with bottom grid and two glass doors for test control.
- Burner BR3 for propane gas equipped with microvalve for flame adjustment.
- 90-degree specimen support sliding system.
- Flame height measuring device (20 mm).
- Flames spacers ISO/DIN (16mm, 5mm) UNI (18mm).
- Mirror inside.
- Tray for "molten dripping".
- Filter paper (50 pcs) 50 x 100mm.
Accessories:
- Specimen holder in stainless steel in compliance with the standard (to your choice)* :
- ISO 11925-2: Samples 110 x 295 mm
- DIN 4102 B2: Samples 90 x 190 + 90 x 230 mm
- UNI 8456 e 8457: Samples 104 x 340 mm
*more specimen holders are available on request
- Table timer:
Liquid crystal display, resolution 1/100 of second, dual mode, time pause function, stop and restart counting without zeroing, etc.
- Hot wire thermo anemometer:
- Telescopic probe - Air speed range: 0 ... +20 m/s.
- Temperature range NTC probe : from -20°C to +70°C.
- Resolutions :0.01 m/s - 0.1°C.
- Working temperature -20 +50°C.
- Power : 1 x 9V battery.