Cod: 150407Standard: None.

The HydroTracer HT3 is a measuring device for the determination of low water contents in solids.

The accuracy of the patented measuring method in connection with relatively high sample quantities enables the measurement of the smallest moisture with a resolution of a few ppm.

A large number of granules, powders and foils can be measured. The HydroTracer is mainly used to determine the residual moisture of plastic granules, where compliance with certain water contents before processing is a quality-determining criterion.

Contact Form

You can get in touch with us filling the contact form below.

REQUEST ESTIMATE
    • Share:

    • Measuring principle: Calcium hydride method.
    • Resolution: 0.01 mg / 1 ppm / 0.0001% H2O.
    • Accuracy: ± 2 % from measuring range end value.
    • Measuring range: 0.2 - 25 mg / 0.0001 - 5 % H2O.
    • Measuring temperatures: 50 - 210 C in 1C steps.
    • Measuring time: 10 - 45 Minutes (typical).
    • Display of results: %, ppm, mg.
    • Interface: USB.
    • Ambient conditions: 5 - 45 °℃, 5 - 95 % rF.

    (See last image):

    1. A material sample is placed in the sample pan and heated. Water steams out of the specimen.
    2. The humid gas flows into the upper, cooled area of the measuring chamber.
    3. The measuring powder contained in a capsule exchanges the water for hydrogen.
    4. The gas sensor measures the hydrogen concentration which equals the introduced amount of water.
    5. The cooled, dry gas sinks into the lower part of the measuring chamber and can absorb water again.